/memberpic/uploadfile/20095/15/200951511556.swf
about-us product factorysupportconfact us

/memberpic/uploadfile/20095/11/2009511144623.swf

Tel: 0769-82980700
Fax:+86-0769-81890449
Email: sales@panfore.com
Website: www.panfore.com

.Universal AC output/Full range
.Built-in active PFC function;
.Protection: short circuit; overload; over voltage;

Specification:

                        Model no.

Item

PFL100W

Output

DC output voltage

+36V

Output rated current

2.8A

Output current range

0-2.8 A

DC output power

100.8W

Ripple & Noise

200mVp-p

DC voltage adj.

------

Output voltage tolerance

±1% (constant voltage)

Output current tolerance

±1% (constant current)

Line regulation

±0.5%

Load regulation

±0.5%

Set up, rise, hold-up time

250ms, 30ms, 20ms/230Vac

Input

Input voltage range

170~264Vac

18-30V dc

Input current

0.7A/220Vac

4.7A/24V dc

Frequency

47~63Hz

------

Power factor

>0.97

------

Efficiency

85%

88%

Inrush current

Cold start  40A/230V

------

Leakage current

<0.5mA/240Vac

------

Protection

Short circuit

Type: Pulsing mode,Reset: auto recovery

Environment

 

 

Working Temp., Humidity

-10~+60@100% LOAD,20%-90% RH 

Storage Temp., Humidity

-20 - +85, 10%-95% RH

Temp. Coefficient

±0.03% /(0-60)

Vibration

10-500Hz, 2G 10min./1cycle, period for 60min. Each axes

 

Safety & EMC

Safety Standard

MEET EN60950,GB4943

Withstand voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms

EMC Standard

MEET EN55022 CLASS B,GB9254 CLASS B

 

Others

Size

200*100*50mm

Weight

1Kg

Remark

1.       All parameters are specified at 230Vac input, rated load,25 70% RH ambient;

2.       Tolerance: includes set up tolerance, line regulation, load regulation,

3.       Ripple & Noise are measured at 20MHz of bandwidth by using a 30cm twisted-pair wire terminated with a 0.1uf & 47uf parallel capacitor;

4.       Line regulation is measured from low line to high line at rated load;

5.  Load regulation is measured from 0%~100% at rated load.

PFL100W.pdf

,r-top-alt: solid windowtext .5pt; mso-borde: solid windowtext .5pt" vAlign=top width=215>

EMC Standard

MEET EN55022 CLASS B,GB9254 CLASS B

 

Others

Size

200*100*50mm

Weight

1Kg

Remark

1.       All parameters are specified at 230Vac input, rated load,25 70% RH ambient;

2.       Tolerance: includes set up tolerance, line regulation, load regulation,

3.       Ripple & Noise are measured at 20MHz of bandwidth by using a 30cm twisted-pair wire terminated with a 0.1uf & 47uf parallel capacitor;

4.       Line regulation is measured from low line to high line at rated load;

5.  Load regulation is measured from 0%~100% at rated load.

PFL100W.pdf

Tel: +86-0769-82980700   Fax: +86-0769-81890449
Panfore Electronics Co.,ltd  粤ICP备09096133号
All rights reserved@ Copyright 2009 [Website management]