.Universal AC output/Full range
.Built-in active PFC function;
.Protection: short circuit; overload; over voltage;
Specification:
|
Model no. Item |
PFL100W | ||
|
Output |
DC output voltage |
+36V | |
|
Output rated current |
| ||
|
Output current range |
0 | ||
|
DC output power |
100.8W | ||
|
Ripple & Noise |
200mVp-p | ||
|
DC voltage adj. |
------ | ||
|
Output voltage tolerance |
±1% (constant voltage) | ||
|
Output current tolerance |
±1% (constant current) | ||
|
Line regulation |
±0.5% | ||
|
Load regulation |
±0.5% | ||
|
Set up, rise, hold-up time |
250ms, 30ms, 20ms/230Vac | ||
|
Input |
Input voltage range |
170~264Vac |
18-30V dc |
|
Input current |
|
| |
|
Frequency |
47~63Hz |
------ | |
|
Power factor |
>0.97 |
------ | |
|
Efficiency |
85% |
88% | |
|
Inrush current |
Cold start |
------ | |
|
Leakage current |
<0.5mA/240Vac |
------ | |
|
Protection |
Short circuit |
Type: Pulsing mode,Reset: auto recovery | |
|
Environment |
Working Temp., Humidity |
-10℃~+ | |
|
Storage Temp., Humidity |
| ||
|
Temp. Coefficient |
±0.03% /℃(0 | ||
|
Vibration |
10-500Hz, | ||
|
Safety & EMC |
Safety Standard |
MEET EN60950,GB4943 | |
|
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
|
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:500VDC / | ||
|
EMC Standard |
MEET EN55022 CLASS B,GB9254 CLASS B | ||
|
Others |
Size |
200*100* | |
|
Weight |
| ||
|
Remark |
1. All parameters are specified at 230Vac input, rated load,25℃ 70% RH ambient; 2. Tolerance: includes set up tolerance, line regulation, load regulation, 3. Ripple & Noise are measured at 20MHz of bandwidth by using a 30cm twisted-pair wire terminated with a 0.1uf & 47uf parallel capacitor; 4. Line regulation is measured from low line to high line at rated load; 5. Load regulation is measured from 0%~100% at rated load. | ||
EMC Standard
MEET EN55022 CLASS B,GB9254 CLASS B
Others
Size
200*100*
Weight
Remark
1. All parameters are specified at 230Vac input, rated load,25℃ 70% RH ambient;
2. Tolerance: includes set up tolerance, line regulation, load regulation,
3. Ripple & Noise are measured at 20MHz of bandwidth by using a 30cm twisted-pair wire terminated with a 0.1uf & 47uf parallel capacitor;
4. Line regulation is measured from low line to high line at rated load;
5. Load regulation is measured from 0%~100% at rated load.

![]() | |
![]() |
Tel: +86-0769-82980700 Fax: +86-0769-81890449 Panfore Electronics Co.,ltd 粤ICP备09096133号 All rights reserved@ Copyright 2009 [Website management] |